1 Scope
This technical requirement stipulates the definition, basic requirements, technical content, and test methods of energy-saving electronic ballast environmental label products.
This technical requirement applies to stand-alone electronic ballasts.
2 reference standards
The clauses contained in the following standards are quoted in this technical requirement and constitute the provisions of this technical requirement, and have the same effect as this technical requirement.
GB 15143−1994 General requirements and safety requirements for AC electronic ballasts for tubular fluorescent lamps
GB/T 15144−1994 AC electronic ballasts for tubular fluorescent lamps Performance requirements When the above standards are revised, the latest version should be used.
3 Definitions
Stand-alone electronic ballasts: Electronic ballasts that can be installed outside the fixture without any additional housing.
4 basic requirements
4.1 The product quality must meet the requirements of GB 15143-1994, GB/T 15144-1994 and so on.
4.2 The discharge of pollutants from enterprises must meet the national or local pollutant discharge standards.
5 technical content
5.1 Line power factor for stand-alone electronic ballast products shall be: λ ≥ 0.95.
5.2 The harmonic current content of the supply current of a stand-alone electronic ballast shall be less than the limit specified in GB/T 15144−1994. See Appendix A.
5.3 The life of a stand-alone electronic ballast should not be less than 10000h.
6 inspection
The detection of line power factor and total harmonic content of the product adopts the methods specified in 5.6 and 5.9 of GB/T 15144−1994, respectively.
Additional information:
This technical requirement is proposed by the Science and Technology Standards Division of the National Environmental Protection Agency.
This technical requirement is interpreted by the National Environmental Protection Agency.
The National Environmental Protection Agency approved 1997−03−14
1997−03−14 implementation
Cotton Braided Sleeve For Computer Cable Harness
Abrasion resistance cable management Polyester Expandable Braided Sleeving
Main features of Cable Braided Sleeve for wire harness
1. Operating temperature: -50°C~150°C
2. Melting point: 250±5°C.
3.Flammability: UL VW-1
4.Standard color: White, Black, Gray,Red, Yellow, Blue,Pink,Orange,Purple,Remix pattern
5.Cutting tool: Hot knife
6. Certificate: RoHS ,MSDS,Halogen Free
Application of Cotton Braided Sleeve For Computer Cable Harness
1. Automobile wires protection
2. Structured cabling system
3.A/V cables & HDMI cables
4.Industrial hoses & tubes protection
Braided Wire Sleeve,Cable Shielding Sleeve,Cable Management Sleeve White,Cotton Sleeve Usb Cable
Shenzhen Huiyunhai Tech.Co.,Ltd , https://www.hyhbraidedsleeve.com