Dimethyl ether detection in liquefied gas
Dimethyl ether is a new type of green environmental protection energy. Its performance is similar to that of liquefied petroleum gas. It is a new type of clean fuel for the substitutive generation of petroleum products. It contains oxygen, a single component, a short carbon chain, good combustion performance, and high thermal efficiency. There is no residual liquid and no black smoke during the process. It is a good, clean fuel. The experimental data shows that the ratio of latent generation to liquefied gas is 1:1 when the ratio of liquefied gas is not more than 25%. To strictly control the proportion of mixed, the autumn and winter season is 1:5 or 1:6, the spring and summer season is 1:4 or 1:3.
The incorporation of dimethyl ether into the liquefied gas enables the combustion of the liquefied gas to be more complete, enabling the residual liquid to be carried out, reducing the possibility of carbon deposition, and reducing the CO and hydrocarbon content in the exhaust gas; in addition, dimethyl ether can also be used. The incorporation of city gas and natural gas in mixed combustion can solve the problem of insufficient gas volume at the peak of city gas, and at the same time improve the gas quality and raise the calorific value.
China Science Spectroscopic Instrument Co., Ltd. has introduced equipment and supporting methods for separating and calculating the content of dimethyl ether in liquefied gas. Currently, most of the liquefied gas in the market is blended with dimethyl ether. Want to know what percentage of liquefied gas components? Is there dimethyl ether in liquefied gas? How much dimethyl ether? In liquefied gas, I want to add dimethyl ether. What is the content after blending? How much is the purity of purchased raw material dimethyl ether?
II. Methodology LPG analysis includes analysis of liquefied gas components and analysis of dimethyl ether and methanol in liquefied gas, excluding alkynes, gas chromatograph with thermal conductivity detector, and various groups of samples in the column. Separation, area normalization method or calibration area normalization method, external standard method to quantify the percentage of each component.
Instruments and materials
1. GC-2020 GC: Thermal Conductivity Detector (TCD)
Air source: Hydrogen as carrier gas, hydrogen purity ≥ 99.9% (steel cylinder or hydrogen generator)
2. Data Processing: N2000 Workstations and Computers
3. Injector: Double six-way valve, quantitative tube 1ml
4. Column: ¢4*10 meters liquefaction gas analysis column ¢3*6 meters dimethyl ether analysis column in liquefied gas
5. Sampler: Stainless steel sampler 4L or sampling bag 1L
6. Standard gas: A bag of dimethyl ether standard gas in liquefied gas (DME content 20%)
Analysis of dimethyl ether in liquefied gas: (¢3*6m)
Zhongkepu Company's After-sale Commitment I. Preparation before Installation
1. The equipment provided by us is of good quality. It is brand new and has not been used. It has passed the factory quality inspection and is well packaged and suitable for long-distance transportation.
2. We will inform the end user of the conditions for the installation of the equipment in written form 10 days before delivery. After receiving the written delivery requirements from the user, we will deliver the goods on time.
Second, install and debug
1. We are responsible for on-site installation and commissioning of the provided equipment until the system is operating normally.
2. After the installation and commissioning is completed, we will train the technicians with more than three years of maintenance experience on the installation site to enable them to independently complete the operations related to the equipment and systems, as well as the matters needing attention during use. The handling of common simple faults ensures that the user can perform skilled operations and routine maintenance on the instrument.
Third, the service provided during the warranty period
1. We guarantee to provide a one-year warranty for the goods, and the warranty time will be calculated from the acceptance signature. During the warranty period, we will strictly abide by the relevant laws and regulations of the People's Republic of China to provide “three guarantees†and other after-sales services for the goods, unless otherwise specified in the contract.
2. During the warranty period, due to the failure of our equipment, we will respond within 24 hours. Within 3 working days after receiving the notice, we shall go to the scene and must continue to repair until the fault is completely eliminated. The device is completely back to normal.
3. We have established (or commissioned) a permanent resident maintenance organization to handle all maintenance services and have a full-time technician with more than three years of relevant work experience. Spare parts and other adequate supply can fully meet the needs of users for one year.
Attachment: National standard liquefied gas components
Name Chemical Formula Content (%) Name Chemical Formula Content (%) Methane CH4 0.01-1 Isobutene C4H8 0.01-10 Ethane C2H4 0.01-1 Butadiene-2 ​​C4H8 0.01-10 Ethylene C2H4 0.01-1 Maleic-2 C4H8 0.01- 10 Propane C3H8 0.01-20 1.3-Butadiene C4H6 0.01-5 Propylene C3H8 0.01-50 Isopentane C5H12 0.01-5 Isobutane C4H10 0.01-20 n-Pentane C5H12 0.01-5 n-Butane C4H10 0.01-20 1- Pentene C5H9 0.01-5 n-butene C4H8 0.01-10 n-hexane C6H14 0.01-2
Zhongkepai Analysis Instrument Co., Ltd. Market Department
Dimethyl ether is a new type of green environmental protection energy. Its performance is similar to that of liquefied petroleum gas. It is a new type of clean fuel for the substitutive generation of petroleum products. It contains oxygen, a single component, a short carbon chain, good combustion performance, and high thermal efficiency. There is no residual liquid and no black smoke during the process. It is a good, clean fuel. The experimental data shows that the ratio of latent generation to liquefied gas is 1:1 when the ratio of liquefied gas is not more than 25%. To strictly control the proportion of mixed, the autumn and winter season is 1:5 or 1:6, the spring and summer season is 1:4 or 1:3.
The incorporation of dimethyl ether into the liquefied gas enables the combustion of the liquefied gas to be more complete, enabling the residual liquid to be carried out, reducing the possibility of carbon deposition, and reducing the CO and hydrocarbon content in the exhaust gas; in addition, dimethyl ether can also be used. The incorporation of city gas and natural gas in mixed combustion can solve the problem of insufficient gas volume at the peak of city gas, and at the same time improve the gas quality and raise the calorific value.
China Science Spectroscopic Instrument Co., Ltd. has introduced equipment and supporting methods for separating and calculating the content of dimethyl ether in liquefied gas. Currently, most of the liquefied gas in the market is blended with dimethyl ether. Want to know what percentage of liquefied gas components? Is there dimethyl ether in liquefied gas? How much dimethyl ether? In liquefied gas, I want to add dimethyl ether. What is the content after blending? How much is the purity of purchased raw material dimethyl ether?
II. Methodology LPG analysis includes analysis of liquefied gas components and analysis of dimethyl ether and methanol in liquefied gas, excluding alkynes, gas chromatograph with thermal conductivity detector, and various groups of samples in the column. Separation, area normalization method or calibration area normalization method, external standard method to quantify the percentage of each component.
Instruments and materials
1. GC-2020 GC: Thermal Conductivity Detector (TCD)
Air source: Hydrogen as carrier gas, hydrogen purity ≥ 99.9% (steel cylinder or hydrogen generator)
2. Data Processing: N2000 Workstations and Computers
3. Injector: Double six-way valve, quantitative tube 1ml
4. Column: ¢4*10 meters liquefaction gas analysis column ¢3*6 meters dimethyl ether analysis column in liquefied gas
5. Sampler: Stainless steel sampler 4L or sampling bag 1L
6. Standard gas: A bag of dimethyl ether standard gas in liquefied gas (DME content 20%)
Analysis of dimethyl ether in liquefied gas: (¢3*6m)
Zhongkepu Company's After-sale Commitment I. Preparation before Installation
1. The equipment provided by us is of good quality. It is brand new and has not been used. It has passed the factory quality inspection and is well packaged and suitable for long-distance transportation.
2. We will inform the end user of the conditions for the installation of the equipment in written form 10 days before delivery. After receiving the written delivery requirements from the user, we will deliver the goods on time.
Second, install and debug
1. We are responsible for on-site installation and commissioning of the provided equipment until the system is operating normally.
2. After the installation and commissioning is completed, we will train the technicians with more than three years of maintenance experience on the installation site to enable them to independently complete the operations related to the equipment and systems, as well as the matters needing attention during use. The handling of common simple faults ensures that the user can perform skilled operations and routine maintenance on the instrument.
Third, the service provided during the warranty period
1. We guarantee to provide a one-year warranty for the goods, and the warranty time will be calculated from the acceptance signature. During the warranty period, we will strictly abide by the relevant laws and regulations of the People's Republic of China to provide “three guarantees†and other after-sales services for the goods, unless otherwise specified in the contract.
2. During the warranty period, due to the failure of our equipment, we will respond within 24 hours. Within 3 working days after receiving the notice, we shall go to the scene and must continue to repair until the fault is completely eliminated. The device is completely back to normal.
3. We have established (or commissioned) a permanent resident maintenance organization to handle all maintenance services and have a full-time technician with more than three years of relevant work experience. Spare parts and other adequate supply can fully meet the needs of users for one year.
Attachment: National standard liquefied gas components
Name Chemical Formula Content (%) Name Chemical Formula Content (%) Methane CH4 0.01-1 Isobutene C4H8 0.01-10 Ethane C2H4 0.01-1 Butadiene-2 ​​C4H8 0.01-10 Ethylene C2H4 0.01-1 Maleic-2 C4H8 0.01- 10 Propane C3H8 0.01-20 1.3-Butadiene C4H6 0.01-5 Propylene C3H8 0.01-50 Isopentane C5H12 0.01-5 Isobutane C4H10 0.01-20 n-Pentane C5H12 0.01-5 n-Butane C4H10 0.01-20 1- Pentene C5H9 0.01-5 n-butene C4H8 0.01-10 n-hexane C6H14 0.01-2
Zhongkepai Analysis Instrument Co., Ltd. Market Department
Toy Sound Module, Musical Module for Toys, Waterproof Sound Module