- Model NO.: ABC
- Conductor Type: Stranded
- Conductor Material: Aluminum
- Insulation Material: XLPE
- Range of Application: Oveahead
- Brand: Huatong
- Color: as Per Your Customers ′ Request
- Trademark: Huatong
- Origin: China
- Type: Insulated
- Application: Overhead, Underground
- Sheath Material: No
- Material Shape: Round Wire
- Certification: ISO9001, CE, CCC, RoHS
- Voltage: LV. Mv. Hv
- Insulated Materials: PVC/PE/XLPE
- Transport Package: All Wooden, Steel Wooden or Steel Package
- HS Code: 8544492100
 ABC Cable
Aluminum Conductor XLPE Insulated ABC Electric Cable
We produce the ABC Electric Cable used for overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM, BS, NF C 33-209 standard.
LV ABC cable(Aerial Bundle cable) with AAAC conductor
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, Duplex, Triplex, Quadruplex.
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.
 Detaild Introduction of Service Drop Cable
1Â Â Duplex Service Drop
Applications: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
Construction: Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.
2Â Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
Construction: Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.
 3 Quadruplex Service Drop
Applications: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction: Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.
Â
Product Description
1.Application:
Pvc insulated abc cable as a new-type aerial cable is used for transmitting electric power overhead, extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.
2.Specification:
Concentric strand aluminum wires as phase conductor; AAAC(all aluminum alloy conductors) or ACSR(aluminum conductor steel reinforced) as messenger (Neutral) core; Phase conductor is insulated by XLPE or HDPE or PVC.
3.Standards:
IEC60502, NF C33-209, GB 12527-90
Rated voltage: 0.6/1kV
Relative manufacturing standards: IEC61089, ASTM B231, ASTM B232, BS215, DIN48201, DIN48204.
4.It meets or exceeds the following specifications:
1. Aluminum Wire, 1350-H19 for Electrical Purposes.
2. Aluminum Conductors, Concentric-Lay-Stranded.
3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. Concentric-Lay-Stranded 6201-T81 Conductors.
5. Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
It meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
5.Construction & descriptions:
specifications        (mm2)                     |
specifications        (mm2) |
specifications        (mm2) |
 specifications        (mm2)   |
1×10 | 1×120+120 | 2×50+50 | 3×10+10 |
1×16 | 1×150+150 | 2×70+70 | 3×16+16 |
1×25 | 1×185+185 | 2×95+95 | 3×25+25 |
1×35 | 1×240+240 | 2×120+120 | 3×35+35 |
1×50 | 1×16+16(Bare) | 2×150+150 | 3×50+50 |
1×70 | 1×25+25(Bare) | 2×185+185 | 3×70+70 |
1×95 | 1×35+35(Bare) | 2×240+240 | 3×95+95 |
1×120 | 1×50+50(Bare) | 2×10+10(Bare) | 3×120+120 |
1×150 | 1×70+70(Bare) | 2×16+16(Bare) | 3×150+150 |
1×185 | 1×95+95(Bare) | 2×25+25(Bare) | 3×185+185 |
1×240 | 1×120+120(Bare) | 2×35+35(Bare) | 3×240+240 |
1×10+10 | 1×150+150(Bare) | 2×50+50(Bare) | 3×16+16(Bare) |
1×16+16 | 1×185+185(Bare) | 2×70+70(Bare) | 3×25+25(Bare) |
1×25+25 | 1×240+240(Bare) | 2×95+95(Bare) | 3×35+35(Bare) |
1×35+35 | 2×10+10 | 2×120+120(Bare) | 3×50+50(Bare) |
1×50+50 | 2×16+16 | 2×150+150(Bare) | 3×70+70(Bare) |
1×70+70 | 2×25+25 | 2×185+185(Bare) |  |
1×95+95 | 2×35+35 | 2×240+240(Bare) |  |
Code word |
AWG or kcmil |
Bare Neutral Messenger |
Phase conductor |
Weight Kg/km |
Allowcable Ampacities(A) |
|||||||
ACSR |
Rated Strength Lbs. |
AAC |
Insul Thick.mm |
XLPE |
PE |
|||||||
Number |
Dia. mm |
Number |
Dia.mm |
Number |
Dia.mm |
|||||||
Setter Shepherd Eskimo Terrier Chow Bull |
1*6AWG+1*6AWG 1*6AWG+1*6AWG 1*4AWG+1*4AWG 1*4AWG+1*4AWG 1*2AWG+1*2AWG 1*1/0AWG+1*1/0AWG |
1 1 1 1 1 1 |
1.68 1.68 2.12 2.12 2.67 3.37 |
6 6 6 6 6 6 |
1.68 1.68 2.12 2.12 2.67 3.37 |
1190 1190 1860 1860 2850 4380 |
1 7 1 7 7 19 |
4.11 1.56 5.19 1.96 2.47 1.89 |
1.14 1.14 1.14 1.14 1.14 1.52 |
111 113 171 173 266 427 |
85 85 115 115 150 205 |
70 70 90 90 120 160 |
Triplex ABC Cable
Code*Word |
Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per 1000 ft.(lbs.) | Allo wable Amp acitles | ||||||
Size (A WG) | Stranding | Insul Thick(Mils) | Size (AWG) | Stranding | Rated Strength (lbs.) | inches | XLP | POLY | XLP | POLY | |
AAC Neutral-messenger | |||||||||||
Pateela | 6 | 7 | 45 | 6 | 7 | 563 | 14.88 | 103 | 103 | 85 | 70 |
Oyster | 4 | 7 | 45 | 4 | 7 | 881 | 14.88 | 154 | 154 | 115 | 90 |
Clam | 2 | 7 | 45 | 2 | 7 | 1350 | 20.58 | 233 | 233 | 150 | 120 |
Murex | 1/0 | 7 | 60 | 1/0 | 7 | 1990 | 20.58 | 374 | 374 | 205 | 160 |
Purpura | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 20.58 | 368 | 368 | 205 | 160 |
Nassa | 2/0 | 7 | 60 | 2/0 | 7 | 2510 | 25.42 | 462 | 462 | 235 | 185 |
Melita | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 29.97 | 562 | 562 | 275 | 215 |
Portunus | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 29.97 | 696 | 696 | 315 | 245 |
Nannynose | 336.4 | 19 | 60 | 336.4 | 19 | 6146 | 38.79 | 1118 | 1118 | 420 | 325 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) +Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun. |
QuadruplexABC Cable
Code*Word |
Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per 1000 ft.(lbs.) | Allo wable Amp acitles | ||||||
Size (A WG) | Stranding | Insul Thick(Mils) | Size (AWG) | Stranding | Rated Strength (lbs.) | inches | XLP | POLY | XLP | POLY | |
AAC Neutral-messenger | |||||||||||
Clydessdale | 4 | 1 | 45 | 4 | 7 | 881 | 20.58 | 198 | 198 | 100 | 80 |
Pinto | 4 | 7 | 45 | 4 | 7 | 881 | 20.58 | 211 | 211 | 100 | 80 |
Mustang | 2 | 7 | 45 | 2 | 7 | 1350 | 25.42 | 318 | 318 | 135 | 105 |
Criollo | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 25.42 | 503 | 503 | 180 | 140 |
Percheron | 2/0 | 11 | 60 | 2/0 | 7 | 2510 | 29.97 | 619 | 619 | 205 | 160 |
Hanovarian | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 35.18 | 764 | 764 | 235 | 185 |
Oldenburg | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 35.18 | 945 | 945 | 275 | 210 |
Lippizaner | 336.4 | 19 | 80 | 336.4 | 19 | 6146 | 38.79 | 1519 | 1519 | 370 | 280 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) +Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec. |
Why Choose us? Â Â
For over 20 years, Huatong Cable INC., which is as a professional cable manufacturer has been producing customized cable for a wide range of applications based on high quality, excellent service and competitive market prices. This is an elite team with experienced personnel and strong technical support. Our achievements benefit by having access to the largest market for cheap labor and abundant resources in China and our determination to exceed our clients' expectations.
Â
Product Feature of Expandable Braided Sleeving
1. PET expandable sleeving is flame-retardant and halogen-free.
2. It offers durable abrasion resistance in a wide range of industrial applications.
3. The open weave construction allows an easy installation on a bundle of hoses and cables, even if some with bulky or large connectors.
4. Totally expanded the sleeving can reach at least one point five times than the initial dimension
Application of PET Expandable Braided Cable Sleeving
used for bonding and protecting electrical cables ,Automotive Wiring Hose in power-supply machine and automobile sectors.
Fire resistance PET braided sleeves for cable management
Main Feature of Braided Cable Sleeve
1) Working Temp: -50~+150C
2) Melting Point: 250C
3) Flame resistant
Cable Braided Sleeve For Wire,Braided Pet Sleeve ,Protect Wire Braid Sleeve,Polyester Braid Sleeve
Shenzhen Huiyunhai Tech.Co.,Ltd , https://www.hyhbraidedsleeve.com